MEP and fire design for industries

Power, fire protection, ventilation and utilities for factories, warehouses and industrial units, designed to the codes your fire authority and insurer expect.

What we design for industrial buildings

SystemWhat we cover
PowerLoad and maximum demand, HT and LT distribution, transformer and DG sizing, power factor correction, cable sizing, and single-line diagrams
Fire protectionYard hydrants, sprinklers for storage and process areas, fire water tanks and pumps, detection and alarm, and drawings for the fire NOC
Lightning and earthingLightning protection risk assessment to IEC 62305-2, air terminals and down conductors, and earthing for equipment and buildings
Ventilation and coolingAir changes for production halls, fresh air and exhaust, spot cooling, and air conditioning for offices, control rooms and labs
UtilitiesWater supply, drainage, sewage treatment, rainwater harvesting, and roads and storm drains inside the plot
EnergyRooftop solar PV sizing and lighting design to cut running costs

Industrial areas we know

In Goa we work in and around the industrial estates at Verna, Kundaim, Cuncolim and Madkaim. Across the border we take on units in the industrial areas of Belagavi, Hubballi, Kolhapur and the Konkan, and we design from your drawings for plants further away.

Insurers and international codes

Insurers and multinational owners often ask for NFPA or other international standards on top of the Indian code. We design to both when needed and show which clause each requirement comes from.

Where we work

From our office in Vasco da Gama we take on projects across Goa and in Karnataka, Maharashtra and Kerala.

We are a young practice. Our completed projects so far are in Goa, and you can see the drawings from each one on our projects page. Every package is calculated, lists the codes it follows, and is prepared by the engineer you speak to.

Frequently asked questions

Something else you'd like to know? Ask us.

Do you design fire hydrant and sprinkler systems for warehouses?

Yes. We design yard hydrants, sprinklers for the storage height and commodity, fire water tanks and pumps, and prepare the drawings for the fire NOC.

Can you design to NFPA for our insurer?

Yes. We design to the Indian code for the approval and to NFPA where your insurer or group standard requires it.

Do you assess lightning protection?

Yes. We carry out a lightning risk assessment to IEC 62305-2 and design the protection system it calls for.

How do you charge?

A fixed fee per service, based on the building and the scope, agreed in writing before we start. Send the drawings and we'll send a quotation.

Have a project coming up? Send us the drawings.

Share the location, building type and what you need. We reply within one working day.