MEP & Fire
Fire NOC in Goa: Which Buildings Need Sprinklers, Hydrants and Fire Alarms?
Getting a fire NOC in Goa: how NBC 2016 Part 4 decides which buildings need sprinklers, hydrants and fire alarms, and how to prepare the drawings.
Power, fire protection, ventilation and utilities for factories, warehouses and industrial units, designed to the codes your fire authority and insurer expect.
| System | What we cover |
|---|---|
| Power | Load and maximum demand, HT and LT distribution, transformer and DG sizing, power factor correction, cable sizing, and single-line diagrams |
| Fire protection | Yard hydrants, sprinklers for storage and process areas, fire water tanks and pumps, detection and alarm, and drawings for the fire NOC |
| Lightning and earthing | Lightning protection risk assessment to IEC 62305-2, air terminals and down conductors, and earthing for equipment and buildings |
| Ventilation and cooling | Air changes for production halls, fresh air and exhaust, spot cooling, and air conditioning for offices, control rooms and labs |
| Utilities | Water supply, drainage, sewage treatment, rainwater harvesting, and roads and storm drains inside the plot |
| Energy | Rooftop solar PV sizing and lighting design to cut running costs |
In Goa we work in and around the industrial estates at Verna, Kundaim, Cuncolim and Madkaim. Across the border we take on units in the industrial areas of Belagavi, Hubballi, Kolhapur and the Konkan, and we design from your drawings for plants further away.
Insurers and multinational owners often ask for NFPA or other international standards on top of the Indian code. We design to both when needed and show which clause each requirement comes from.
From our office in Vasco da Gama we take on projects across Goa and in Karnataka, Maharashtra and Kerala.
We are a young practice. Our completed projects so far are in Goa, and you can see the drawings from each one on our projects page. Every package is calculated, lists the codes it follows, and is prepared by the engineer you speak to.
Articles from our engineers on building on the west coast. All articles

MEP & Fire
Getting a fire NOC in Goa: how NBC 2016 Part 4 decides which buildings need sprinklers, hydrants and fire alarms, and how to prepare the drawings.

Structural & PEB
PEB vs conventional steel building: how they differ, where each makes sense, and what to decide early when planning a warehouse or factory.

MEP & Fire
Why earthing is hard in Goa's laterite and coastal sand, how many earth pits a building needs, how to calculate the resistance, and when to test.
Something else you'd like to know? Ask us.
Yes. We design yard hydrants, sprinklers for the storage height and commodity, fire water tanks and pumps, and prepare the drawings for the fire NOC.
Yes. We design to the Indian code for the approval and to NFPA where your insurer or group standard requires it.
Yes. We carry out a lightning risk assessment to IEC 62305-2 and design the protection system it calls for.
A fixed fee per service, based on the building and the scope, agreed in writing before we start. Send the drawings and we'll send a quotation.
Share the location, building type and what you need. We reply within one working day.