MEP & Fire
Earthing Design in Goa: Laterite, Coastal Sand and Getting the Resistance Down
Why earthing is hard in Goa's laterite and coastal sand, how many earth pits a building needs, how to calculate the resistance, and when to test.
Building services and fire protection design for homes, hotels, apartments and industry across Goa and the west coast, and subsea engineering for cables and pipelines. Every package is calculated and code-referenced, and you deal directly with the engineer who designs it.
Electrical, plumbing and HVAC design, with the loads, tanks and pumps calculated.
MEP designSprinklers, hydrants and fire alarm, and the drawings for the fire NOC.
Fire protection designRoute, burial, landfall and installation engineering for submarine cables and pipelines.
Marine and Subsea EngineeringDesigned to Indian codes, and to international codes when your project needs them
Each service is delivered as a complete drawing package: notes, calculations, layouts, schematics and details, so the electrician, plumber, HVAC or fire contractor has what they need.
Electrical, plumbing and HVAC from one team, with fire protection designed alongside, so the services share the shafts and ceilings instead of fighting for them.
Power, lighting and earthing for homes, apartments and commercial buildings, sized from load, cable and lighting calculations.
Water supply and drainage for villas, apartments and mixed-use buildings, sized from fixture-unit and demand calculations.
Air conditioning and ventilation sized from room-by-room heat loads and fresh-air rates, with ducts sized by calculation.
Fire fighting and fire alarm systems sized to the building's height and use, with drawings for the fire NOC.
Internal roads and the services in them for plotted layouts, designed in AutoCAD Civil 3D.
We are new, so we would rather show you our drawings than a long client list. Each project page has sheets from the package we issued. All projects

Downcomer, hose reels, basement and shop sprinklers, terrace tank and fire pump, to NBC 2016 and IS 15105.
View project
75,000 L sump, 30,000 L overhead tank, grey, black and rainwater stacks carried below the stack parking.
View project
Water demand for fourteen occupants, booster pumps, 500 L/day solar hot water and drainage for every bathroom.
View project
Road alignment, U-drains, sewer, water mains, hydrants and street lighting, designed in AutoCAD Civil 3D.
View projectA small practice judged by its drawings. More about IMI Design
Electrical load and cable sizes, heat loads, water demand, pump duty and fire water requirements are worked out and stated on the drawings, so anyone can check how a size was chosen.
Each package lists the codes it follows in its general notes, so the fire department, the municipality and your contractor can see the basis of design.
The person preparing your drawings answers your calls and meets you at our office in Vasco. No account managers, no hand-offs.
Indian codes are the basis of every design. When a client, insurer or brand standard calls for international codes, we design to those as well, and the codes used are listed on every sheet.
SP 7:2026 (NBCS 2026), or NBC 2016 where the authority still applies it, with the National Electrical Code, the CEA safety regulations, IS 732, IS 3043, IS 3646, IS 1172, IS 15105 and IS 2189, and CPHEEO, IRC and MoRTH for infrastructure.
IEC 60364 and BS 7671 for wiring, BS 7430 for earthing and EN 12464-1 for lighting, when a project specifies them.
NFPA 13 sprinklers, NFPA 14 standpipes, NFPA 20 fire pumps and NFPA 72 fire alarm, where the client, insurer or brand standard asks for them.
ASHRAE 62.1 ventilation, ASHRAE 90.1 energy and ASHRAE load calculation methods, alongside ISHRAE and the building services part of the Indian code.
The Uniform or International Plumbing Code, or BS EN 806 and BS EN 12056, when a project specifies them instead of NBC Part 9.
A simple sequence, so you know what happens at each step and what you'll receive. Drawing names, status codes and revisions follow ISO 19650 conventions, so you always know which drawing is current and what it has been issued for.
Plans, sections and the site location. We confirm what we need and ask any questions.
A written scope and quotation for the drawing package before any work starts.
Electrical load, cable and lighting, heat load and ducts, water demand and pumps, fire water or road levels, to the codes agreed.
Issued to you for review, with a drawing register and issue sheet for every issue.
Drawings for authority submissions, and answers to contractor questions during construction.
From our office in Vasco da Gama we design projects across Goa and in neighbouring Karnataka, Maharashtra and Kerala, for the people who plan, build and engineer them.
Practical guides on electrical, plumbing, HVAC and fire protection design. All articles

MEP & Fire
Why earthing is hard in Goa's laterite and coastal sand, how many earth pits a building needs, how to calculate the resistance, and when to test.
MEP & Fire
ERV, HRV, DOAS or an ERV with its own dehumidifier? A worked Goa office example, plus filtration, automation and new technology for humid coastal buildings.
MEP & Fire
Low-GWP refrigerants, oil-free chillers, radiant cooling, AI controls and more: which new HVAC technology suits Goa's humid coastal climate, and which doesn't.
Something else you'd like to know? Ask us.
An MEP consultant designs a building's mechanical (air conditioning and ventilation), electrical and plumbing systems, and usually its fire protection too: calculating loads, sizing cables, ducts, pumps, tanks and pipes, and producing the drawings contractors build from. See our MEP design service.
Yes. We design fire fighting and fire alarm systems to NBCS 2026 Part F (or NBC 2016 Part 4 where the authority still applies it) for the building's height and use, and prepare the drawings needed for the fire NOC. See fire protection design.
Yes. Indian codes are the basis of every design, and when a client, insurer or brand standard asks for NFPA, ASHRAE, IEC, BS 7671, UPC, IPC or BS EN, we design to those too and list them on the drawings.
Send us the architectural drawings or a short description: location, building type, built-up area and which services you need. We usually reply with questions or a fee proposal within one working day. Contact us.
Share the location, building type and what you need. We reply within one working day.