MEP & Fire
HVAC for Villas and Hotels in Goa: Split, VRF or Chilled Water?
HVAC for villas and hotels in Goa: split AC, VRF or chilled water? A practical comparison, with tips on humidity, fresh air and running costs.
Find what size of split AC a room needs, in tons, from its size, whether it gets the sun or sits under the roof, and how many people use it.
Result
–
An estimate for early planning, not a design. Your building, site and authority can change the answer.
It adds up the heat a room gains on a hot, humid afternoon and converts it to tons of refrigeration (1 ton = 3.517 kW):
The result is rounded up to the next split AC size: 0.75, 1, 1.5 or 2 tons. Above 2 tons, a room is better served by two units or a cassette or ducted unit.
"One ton per 100 sq ft" ignores the things that matter most: a west-facing glass wall can double the load of a room, and a top-floor room under a concrete roof gains far more heat than the same room below it. An oversized AC is no better: it cools the air quickly, switches off before it has removed the moisture, and leaves the room cold and damp, which on the coast means mould.
For a whole house, an office floor or a hotel, a proper heat load calculation sizes every room and the outdoor units together. That is part of our HVAC design.
Articles from our engineers on building on the west coast. All articles

MEP & Fire
HVAC for villas and hotels in Goa: split AC, VRF or chilled water? A practical comparison, with tips on humidity, fresh air and running costs.
MEP & Fire
ERV, HRV, DOAS or an ERV with its own dehumidifier? A worked Goa office example, plus filtration, automation and new technology for humid coastal buildings.
MEP & Fire
Low-GWP refrigerants, oil-free chillers, radiant cooling, AI controls and more: which new HVAC technology suits Goa's humid coastal climate, and which doesn't.
Something else you'd like to know? Ask us.
For a 150 sq ft bedroom on a middle floor with shaded windows and two people, about 1 ton. If it is on the top floor and its windows also get the afternoon sun, 1.5 tons.
No. An oversized AC switches on and off often and doesn't run long enough to remove moisture, so the room feels cold and clammy. Size it to the load, and choose an inverter AC so it can run slower when the load is lower.
No. It is for one room. For a house, office or hotel, a heat load calculation for every space, and the choice between split, VRF and chilled water systems, is part of a proper HVAC design.
We'll reply within one working day with what the building needs and a fixed fee for the design.