AC tonnage calculator

Find what size of split AC a room needs, in tons, from its size, whether it gets the sun or sits under the roof, and how many people use it.

Your room

Results update as you type.

Result

–

    An estimate for early planning, not a design. Your building, site and authority can change the answer.

    How this calculator works

    It adds up the heat a room gains on a hot, humid afternoon and converts it to tons of refrigeration (1 ton = 3.517 kW):

    • Walls, roof and windows: 140 W per m² of floor for a shaded middle-floor room, plus 40 W/m² for windows that get the sun and 40 W/m² for a room under the roof, scaled up for ceilings higher than 3 m
    • People: 130 W each, seated or doing light work
    • Lights: 8 W per m² for LED lighting
    • Equipment: a TV in a living room, computers in an office, and so on
    • Fresh air and humidity: 10% extra for outside air and the moisture the AC has to remove in a coastal climate

    The result is rounded up to the next split AC size: 0.75, 1, 1.5 or 2 tons. Above 2 tons, a room is better served by two units or a cassette or ducted unit.

    Why rules of thumb get it wrong

    "One ton per 100 sq ft" ignores the things that matter most: a west-facing glass wall can double the load of a room, and a top-floor room under a concrete roof gains far more heat than the same room below it. An oversized AC is no better: it cools the air quickly, switches off before it has removed the moisture, and leaves the room cold and damp, which on the coast means mould.

    For a whole house, an office floor or a hotel, a proper heat load calculation sizes every room and the outdoor units together. That is part of our HVAC design.

    More free calculators

    Frequently asked questions

    Something else you'd like to know? Ask us.

    How many ton AC do I need for a 150 sq ft room?

    For a 150 sq ft bedroom on a middle floor with shaded windows and two people, about 1 ton. If it is on the top floor and its windows also get the afternoon sun, 1.5 tons.

    Is a bigger AC better?

    No. An oversized AC switches on and off often and doesn't run long enough to remove moisture, so the room feels cold and clammy. Size it to the load, and choose an inverter AC so it can run slower when the load is lower.

    Does this work for a whole building?

    No. It is for one room. For a house, office or hotel, a heat load calculation for every space, and the choice between split, VRF and chilled water systems, is part of a proper HVAC design.

    Want the real numbers for your building? Send us the drawings.

    We'll reply within one working day with what the building needs and a fixed fee for the design.